Replacement panels and new specifications
Choosing mineral-fibre ceiling tiles
Match the panel’s material, edge and declared performance to the ceiling already in place or the room you are creating.

Mineral-fibre ceiling tiles combine a fibrous core with a finished face and an edge designed for a particular grid. They can provide useful sound absorption while allowing access above the ceiling. The face may look plain from the floor, but the core, backing and edge all matter. Choosing a replacement by colour and square size alone can change the appearance, fit and performance of the ceiling.
What is inside the tile?
Stone wool is one type of mineral-fibre core. Sound entering its porous structure loses energy rather than being reflected entirely back into the room. The decorative surface has to work with that core, so a tile’s finish is part of its acoustic design. Covering it with an unapproved coating is not equivalent to repainting an ordinary plastered ceiling.
Some products add a backing designed to restrict transmission through the ceiling. Rockfon Sonar dB 35, for example, uses a 25 mm stone-wool core with a membrane on the reverse. The backing has a different purpose from the visible finish: it contributes to the product’s room-to-room sound-insulation performance.
Gypsum tiles are a separate construction. Knauf Danotile has a foil-covered gypsum face intended for cleaning and hygiene requirements. It is a useful alternative to consider where cleaning is the priority, but it should not be described as the same material or assumed to provide the same absorption as a mineral-fibre acoustic panel.
Read an acoustic result with its test arrangement
Rockfon’s September 2024 sheet gives a weighted absorption coefficient, αw, of 0.80 and Class B for the listed Sonar dB 35 arrangement: 25 mm tiles, A24/E15/E24 edges and 200 mm suspension height. Knauf’s February 2025 Danotile sheet reports αw 0.10, without an absorption class, at 200 mm suspension depth with no mineral wool. These examples show why “white ceiling tile” is not an acoustic specification.
The coefficient summarises measured absorption; it is not the percentage by which a room’s noise level will fall. A room with only a small treated area, a large glazed wall and hard flooring may need a different acoustic design from a carpeted room with a fully treated ceiling. The area, frequency behaviour and other surfaces all affect the result.
Nor does absorption establish privacy between adjacent rooms. Sound can pass through the ceiling and shared void, through partitions or around doors. Room-to-room insulation data concerns a different test and should be assessed with the actual room boundaries. This distinction matters when replacing tiles over enclosed offices as well as when fitting a new open-plan room.
Scroll sideways to see the full table. Keyboard: focus the table, then use the arrow keys.
| Example | Construction or published result | Selection implication |
|---|---|---|
| Rockfon Sonar dB 35 | 25 mm stone wool with rear membrane | Combines absorption and a documented sound-insulation function |
| Sonar dB 35 listed arrangement | αw 0.80, Class B at 200 mm suspension | Use the stated edges and test configuration when assessing the figure |
| Knauf Danotile UK February 2025 sheet | αw 0.10 at 200 mm, no mineral wool | A cleanable gypsum example is not automatically an absorptive substitute |
The edge changes how the ceiling looks and fits
A square lay-in edge sits on the visible grid flange. A recessed edge has a shoulder that bears on the grid while the face sits lower, leaving a shadow line. Concealed-edge arrangements hide more of the support, but have their own installation and access requirements. These are physical differences, not merely alternative names for the same square tile.
Compare the product drawing with the retained ceiling. Rockfon’s T24 A and T24 E systems both use a 24 mm wide grid, but the tile edges produce different relationships between panel face and grid. The number 24 describes the visible grid width; it does not tell you the panel thickness.
An edge photograph and product reference can prevent an expensive mismatch. Where the original product is no longer available, a proposed alternative needs assessment for its support, appearance and required performance. A panel cut down to fit an opening may lose the edge that was intended to carry it.

Cleaning and moisture need their own specification
A washable face can be valuable where routine cleaning is part of the room’s operation. The cleaning method still has to suit the named product. A soft porous surface, a painted fleece and a foil facing will not necessarily tolerate the same treatment. Trial cleaning and the manufacturer’s instructions are more useful than assuming that every white panel can be scrubbed.
Humidity resistance also differs from surviving a plumbing leak. A product may remain dimensionally stable in humid air yet still need replacement after damage, contamination or prolonged direct wetting. The metal grid and its corrosion resistance need consideration separately from the tile. A suitable panel does not make every support system suitable for a damp environment.
In refurbishment, address the water source before choosing a replacement. Staining confined to one bay may reveal a local leak; widespread deterioration can require a broader investigation. The appearance of the new tile should be the last part of that decision, after the room conditions and retained support are understood.
Fire information belongs to the complete arrangement
Reaction-to-fire classification describes how a product behaves when exposed to fire. Fire resistance describes how a construction performs for a period under a specified test. They answer different questions. A tile’s classification cannot be read as a number of minutes for the whole ceiling.
Where the ceiling contributes to the required fire performance, use the documented assembly. Tile type, edge, grid, clips, perimeter and the construction above can be relevant. A replacement lighting unit or service opening may also affect that arrangement. The installer and designer need the applicable detail before a substitute tile is accepted.
For an old installation, material identification comes before opening it up. HSE identifies asbestos insulating board among possible ceiling tiles. Existing records and an appropriately scoped investigation should establish what can be disturbed; guessing from texture or colour is not a reliable check.
Retain the grid only when it remains suitable
A tile-only refresh can reduce the work where the existing support is sound and compatible. Look beyond the visible paint: distorted tees, damaged connections, inappropriate hangers and poorly supported fittings can make a new surface a false economy. The ceiling must also meet the intended specification after the change.
If the grid is retained, a sample panel should fit and sit correctly without forcing the frame. Check the border treatment and access clearance, not just an easy central bay. For a wider replacement, set out the grid with the lights and ventilation fittings so that cut edges and service positions look deliberate.
Finish the job with identifiable spare stock and the exact product reference. Maintenance teams can then replace a damaged panel without repeating the whole identification exercise. Keep the cartons dry and protected, and retain the cleaning instructions with the building’s maintenance information.

Questions and answers
Are all mineral-fibre tiles acoustic?
Mineral-fibre products have different absorption performance. Compare the declared result for the intended installation; the material name alone does not say how much treatment a room needs.
Can a washable tile replace an absorptive panel?
Yes, if it also meets the room’s acoustic, fire and fitting requirements. Cleanability alone is insufficient: the replacement may have different absorption or sound-insulation properties.
Can ceiling tiles be painted?
Only where the exact product’s instructions allow it. An unapproved coating can change the face and acoustic behaviour; otherwise consider an appropriate replacement panel.
Sources and further reading
- Rockfon Sonar dB 35 product datasheetSource checked: 29 October 2026
- Knauf UK Danotile product data sheet, revision002 27 February 2025Source checked: 30 October 2026
- Knauf Insulation acoustic principlesSource checked: 29 October 2026
- Rockfon System T24 ASource checked: 30 October 2026
- Rockfon System T24 ESource checked: 30 October 2026
- Rockfon moisture and humidity FAQSource checked: 29 October 2026
- Rockfon: fire-safety questionsSource checked: 29 October 2026